Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Intervalo de ano de publicação
2.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-782361

RESUMO

BACKGROUND@#MAVERIC (Mitral Valve Repair Clinical Trial) validates the safety and efficacy of the ARTO system. We here report the first two successful cases of utilizing the ARTO system in patients with symptomatic heart failure (HF) with functional mitral regurgitation (FMR) in Asia.@*METHODS@#Two patients, aged 70 and 63, had severe HF with FMR. Transesophageal echocardiography confirmed that the left ventricular ejection fractions were less than 50% with severe mitral regurgitation (MR) in both patients. Optimizing drug treatment could not mitigate their symptoms. Therefore, we used the ARTO system to repair the mitral valve for these patients on March 5 and 6, 2019, respectively.@*RESULTS@#Mitral valve repairs using the ARTO system were successfully performed under general anaesthesia for these two patients. MR was decreased immediately after the procedures in both patients. The 30-day and 3-month transthoracic echocardiography (TTE) revealed a moderate to severe MR in both patients, and the New York Heart Association (NYHA) scales were also partially improved.@*CONCLUSION@#The first two cases in Asia indicate that the ARTO system is feasible for patients with heart failure with FMR, and the patient selection appears to be crucial.

3.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-787596

RESUMO

BACKGROUND@# Stent failure is more likely in the lipid rich and thrombus laden culprit lesions underlying ST-segment elevation myocardial infarction (STEMI). This study assessed the effectiveness of post-dilatation in primary percutaneous coronary intervention (pPCI) for acute STEMI.@*METHODS@# The multi-center POST-STEMI trial enrolled 41 consecutive STEMI patients with symptom onset <12 hours undergoing manual thrombus aspiration and Promus Element stent implantation. Patients were randomly assigned to control group (n=20) or post-dilatation group (n=21) in which a non-compliant balloon was inflated to >16 atm pressure. Strut apposition and coverage were evaluated by optical coherence tomography (OCT) after intracoronary verapamil administration via thrombus aspiration catheter, post pPCI and at 7-month follow-up. The primary endpoint was rate of incomplete strut apposition (ISA) at 7 months after pPCI.@*RESULTS@# There were similar baseline characteristics except for stent length (21.9 [SD 6.5] mm vs. 26.0 [SD 5.8] mm, respectively, P=0.03). In post-dilatation vs. control group, ISA rate was lower (2.5% vs. 4.5%, P=0.04) immediately after pPCI without affecting final TIMI flow 3 rate (95.2% vs. 95.0%, P>0.05) or corrected TIMI frame counts (22.6±9.4 vs. 22.0±9.7, P>0.05); and at 7-month follow-up (0.7% vs. 1.8%, P<0.0001), the primary study endpoint, with similar strut coverage (98.5% vs. 98.4%, P=0.63) and 1-year rate of major adverse cardiovascular events (MACE).@*CONCLUSION@# In STEMI patients, post-dilatation after stent implantation and thrombus aspiration improved strut apposition up to 7 months without affecting coronary blood flow or 1-year MACE rate. Larger and longer term studies are warranted to further assess safety (ClinicalTrials.gov identifi er: NCT02121223).

4.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-782530

RESUMO

BACKGROUND@#Current data is lacking about the progression of ascending aortic dilatation after transcatheter aortic valve replacement (TAVR) in aortic stenosis (AS) patients with bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV). This study aims to assess the ascending aortic dilatation rate (mm/ year) after TAVR in patients with BAV versus TAV using a multidetector computed tomography (MDCT) follow-up and to determine the predictors of ascending aortic dilatation rate.@*METHODS@#Severe AS patients undergoing TAVR from March 2013 to March 2018 at our center with MDCT follow-ups were included. BAV and TAV were identified using baseline MDCT. Baseline and follow-up MDCT images were analyzed, and the diameters of ascending aorta were measured. Study end point is ascending aortic dilatation rate (mm/year). Furthermore, factors predicting ascending aortic dilatation rate were also investigated.@*RESULTS@#Two hundred and eight patients were included, comprised of 86 BAV and 122 TAV patients. Five, 4, 3, 2, and 1-year MDCT follow-ups were achieved in 7, 9, 30, 46, and 116 patients. The ascending aortic diameter was significantly increased after TAVR in both BAV group (43.7±4.4 mm vs. 44.0±4.5 mm; P<0.001) and TAV group (39.1±4.8 mm vs. 39.7±5.1 mm; P<0.001). However, no difference of ascending aortic dilatation rate was found between BAV and TAV group (0.2±0.8 mm/year vs. 0.3±0.8 mm/year, P=0.592). Multivariate linear regression revealed paravalvular leakage (PVL) grade was independently associated with ascending aortic dilatation rate in the whole population and BAV group, but not TAV group. No aortic events occurred during follow-ups.@*CONCLUSION@# Ascending aortic size continues to grow after TAVR in BAV patients, but the dilatation rate is mild and comparable to that of TAV patients. PVL grade is associated with ascending aortic dilatation rate in BAV patients post-TAVR.

5.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-787539

RESUMO

BACKGROUND@#Transapical off-pump NeoChord procedure is a novel minimally invasive surgical repair of degenerative mitral regurgitation (MR). Here, we report the first four cases of NeoChord procedure in patients with mitral valve prolapse in Chinese mainland.@*METHODS@#Four patients, aged 86, 84, 80 and 60 years, with severe MR due to posterior middle scallop prolapse (P2), underwent transapical off-pump artificial chordae implantation on April 9 and 10, 2019. The procedure was performed by left mini-thoracotomy under general anaesthesia and guided by 2D and 3D dimensional transoesophageal echocardiography (TEE).@*RESULTS@#Mitral valve repair via NeoChord procedure was successfully performed with implantation of 3 artificial chordae in the first patient and 3, 2, and 3 artificial chordae in the following patients, respectively. Intraoperative TEE and pre-discharge transthoracic echocardiography (TTE) showed only mild to moderate MR of these four patients and no postoperative complications were noted. There were no changes of TTE finding between one-month follow-up and pre-discharge.@*CONCLUSION@#The successful NeoChord procedures in four Chinese indicate that the valve repair using the NeoChord system for Chinese population is feasible.

6.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-789828

RESUMO

BACKGROUND:No retrievable and repositionable second generation transcatheter aortic valve is available in China. Here, we report the first-in-man implantation of the retrievable and repositionable VenusA-Plus valve. METHODS:A 76-year-old patient with symptomatic severe aortic stenosis and high surgical risk (STS 13.8%) was recommended for transcatheter aortic valve replacement (TAVR) by heart valve team. Type 0 bicuspid aortic valve with asymmetric calcification was identified by dual source computed tomography, and the unfavorable anatomies increased the possibility of malposition and paravalvular leakage during TAVR. Therefore, we used the retrievable and repositionable VenusA-Plus valve for the patient. RESULTS:Transfemoral TAVR was performed under local anesthesia with sedation, and a 26-mm VenusA-Plus valve was successful y implanted. No transvalvular pressure gradient and trace paravalvular leakage were found. CONCLUSION:The successful first-in-man implantation indicates the retrievable and repositionable VenusA-Plus valve is feasible in complicated TAVR cases such as bicuspid aortic valve.

7.
Chinese Medical Journal ; (24): 2000-2005, 2015.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-335669

RESUMO

<p><b>BACKGROUND</b>Fractional flow reserve (FFR) is currently considered as the gold standard for evaluating the functional significance of coronary stenosis. However, its potential benefits in real-world practice remain unknown in China. This study aimed to test the hypothesis that the use of FFR is associated with improved outcome and reduced cost in Chinese real-world clinical practice.</p><p><b>METHODS</b>A retrospective cohort study was carried out using the database of Second Affiliated Hospital of Zhejiang University, a tertiary and high-volume center in China. Clinical events were compared using the Cox proportional hazards model during a median follow-up of 13 months.</p><p><b>RESULTS</b>The study cohort consisted of 366 consecutive patients referred for coronary revascularization with adjunct FFR and 366 matched controls, from 2010 to 2014. Major adverse cardiac events (MACEs) (death, myocardial infarction, repeated revascularization, or hospitalization for angina) at 4 years were found in 12.0% of angiography-guided patients and 4.9% in the FFR-guided group (P < 0.001). The mean number of implanted stents was significantly lower in FFR treated subjects (0.52 ± 0.82 stents) compared with the angiography-guided group (0.93 ± 0.96 stents) (P < 0.001). No difference in overall costs at initial hospitalization was observed between angiography-guided percutaneous coronary intervention (PCI) compared with FFR-guided PCI (RMB 33,000 Yuan, range: RMB 7393-44,700 Yuan) versus RMB 21,200 Yuan (RMB 19,100-47,100 Yuan) (P = 0.54). However, costs for MACEs during follow-up were significantly reduced in the FFR-guided arm (P < 0.001).</p><p><b>CONCLUSIONS</b>In the contemporary clinical practice, FFR-guided PCI is associated with decreased use of stents, improved clinical outcome, and reduced costs, compared with angiography-guided PCI.</p>


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , China , Custos e Análise de Custo , Reserva Fracionada de Fluxo Miocárdico , Fisiologia , Intervenção Coronária Percutânea , Economia , Métodos , Estudos Retrospectivos
8.
Chinese Medical Journal ; (24): 155-160, 2008.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-255748

RESUMO

<p><b>BACKGROUND</b>Mesenchymal stem cells are a promising cell type for cell transplantation in myocardial infarction. Type I neuregulins-1, also known as heregulin, can promote the survival of cardiomyocytes and stimulate angiogenesis. The purpose of this study was to investigate the expression of heregulin and ErbB receptors in mesenchymal stem cells, then further detect the secretion of heregulin and the changes in expression of heregulin and ErbB receptors under conditions of serum deprivation and hypoxia.</p><p><b>METHODS</b>Mesenchymal stem cells isolated from bone marrow of 180 g male Sprague-Dawley rats were cultured. Passage 3 cells were detected experimentally by regular reverse transcriptase-polymerase chain reaction (RT-PCR), quantitative real time PCR and Western blotting.</p><p><b>RESULTS</b>Heregulin and ErbB receptors were expressed in mesenchymal stem cells, and all three ErbB receptors mRNA expressions were significantly down-regulated by serum deprivation and hypoxia, but serum deprivation and hypoxia significantly increased the protein expression of heregulin. Serum deprivation and hypoxia more than 12 hours could induce the secretion of heregulin.</p><p><b>CONCLUSIONS</b>Mesenchymal stem cells can express all three ErbB receptors and heregulin. Serum deprivation and hypoxia decrease the mRNA expression of ErbB receptors, increase the expression of heregulin, and activate the secretion of heregulin.</p>


Assuntos
Animais , Masculino , Ratos , Hipóxia Celular , Células Cultivadas , Células-Tronco Mesenquimais , Química , Metabolismo , Neuregulina-1 , Genética , Proteínas Oncogênicas v-erbB , Genética , RNA Mensageiro , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...